Toggle Nav
My Cart
1756-IB16S

1756-IB16S CONTROL LOGIX SAFETY IO MODULE

Rating:
0 % of 100
10-30 VDC Safety Input 16 Pts (36 Pin)
1756-IB16S CONTROL LOGIX SAFETY IO MODULE is available to buy in increments of 1
0 pcs
3.377,77 RON
(price per 1 pcs ordered)
Enquiry
Overview
1756 ControlLogix chassis-based modules provide a full range of digital, diagnostic digital, analog, motion control, specialty I/O, and compute modules to meet your application needs. You can use any of the chassis-based modules in the local chassis of a ControlLogix controller or in a chassis linked to a ControlLogix controller across ControlNet or EtherNet/IP networks.Mounts in a ControlLogix chassis Requires either a removable terminal block (RTB) or a Bulletin 1492 wiring interface module (IFM) to connect all field-side wiring Includes inherent time-stamping capabilities for sequence of events (SOE) applications Offers EtherNet/IP communication, including CIP Security and redundancy capability Offers comprehensive I/O diagnostics for detection of both system and field-side failures Provides removal and insertion under power (RIUP) for ease of maintenance Offers electronic keying to help prevent replacement errors Includes I/O wizards in the Studio 5000 Logix Designer application to enable quick and easy module configuration 1756 ControlLogix CIP Safety I/0 Modules Supports Compact GuardLogix 5380 or GuardLogix 5580 controllers Offers functional safety rated up to and including SIL3 and PLe Supports CIP safety bridging and routing functionality Use as local I/O or distributed I/O with 5580 GuardLogix controller Provides enhanced reaction time Uses the Logix Designer application version 32 Offers digital input modules: IB16S 16 channels (each SIL 3 rated) Offers digital output modules: OBV8S 8 channels (each SIL 3 rated) Includes compliance markings: T V, UL, IECEx, ATEX, CE, Marine, FM ControlLogix Digital I/O Modules Offers a variety of voltages Provides 8 to 32 points per module Offers isolated and non-isolated module types Includes point-level output fault states Offers direct-connect or rack-optimized communication Offers field-side diagnostics on select modules 1756 ControlLogix Analog I/O Modules Includes input, output, and combination modules Provides thermocouple and RTD modules Includes on-board data alarming Offers scaling to engineering units Provides real-time channel sampling Offers electronic module keying, and is software configurable Includes mechanical RTB keying, user-defined Offers per channel configuration for voltage, current or 2-wire transmitter current sourcing Offers Per channel configuration for either RTD or Thermocouple As of March 31, 2017, the ControlLogix 1756 Isolated Analog I/O 6-channel modules will be discontinued and no longer available for sale. Customers are encouraged to migrate to the 1756 Isolated Analog I/O 8-channel modules using the Migrating 6-channel to 8-channel 1756 Analog Modules Migration Guide 1756 ControlLogix Specialty I/O Modules Includes configurable flow meter modules Provides high-speed counter modules Offers programmable limit switch modules 1756 ControlLogix Removable Terminal Blocks (RTBs) Provides a flexible interconnection between plant wiring and I/O modules Includes screw-clamp or spring-clamp terminations Not shipped with I/O modules; you must order separately 1756 HART Analog Isolated I/O Modules Includes channel-to-channel isolation Offers HART modem per channel for faster HART data update Offers basic field device configuration via the Add-on Profile Helps eliminate the need for field isolating barriers when using isolated modules Offers 8- or 16-channel density modules 1756 Enhanced Analog I/O Modules Offers increased accuracy, repeatability, stability, and precision Includes isolated 8-channel and non-isolated 12- and 16-channel modules with stability over the entire temperature operating range Does not require field calibration Offers advanced precision using 24-bit design Includes per channel status and fault LED annunciation Offers SIL 1, systematic capability 2, type certified for use in a ControlLogix SIL 2 architecture Offers an emulation mode that helps enable customers to migrate from 6-channel applications 1756 Communications Modules Implements network-based access control for users, devices, and networks in the 1756 chassis Offers redundancy capabilities Offers security modules to encrypt important information shared between controllers and servers to prevent tampering 1756 Compute Module Provides high-speed access to the ControlLogix controller over the backplane Integrated DisplayPort for direct connection to a high-definition 5100 industrial monitor Provides computing capability in a ControlLogix chassis
Technical specifications
Function Display
Product Reviews
0
Rating:
0 % of 100
0 Review
5 Stars
0% (0)
4 Stars
0% (0)
3 Stars
0% (0)
2 Stars
0% (0)
1 Star
0% (0)

Your opinion matters,

Give this product a rating:

Reviews
Write Your Own Review
You opinion matters, Write a review!
Your Rating

IMPORTANT: Please note that all product information, associated resources and links to third party websites contained within our website have been prepared solely for the purpose of providing general information only. All information is provided in good faith as a convenience to you and may be always used for information purposes and guidance only and in accordance with our Terms & Conditions of sale. Due to the reliance on third party data, we are unable to guarantee that the content on our sites is accurate, complete, or up to date at any given time and it is recommended that if you are unsure if a product will fulfil all your requirements that you always seek specialist advice from your local Vestra branch before making your selection.